Gulfaar Logo
Gulfaar Oman Regional Branch
Fortune Energy & Integrated Services LLCPower Generation & Industrial Services

Power Generation,
400kV Substation Commissioning
& Industrial Plant Services

Fortune Energy & Integrated Services LLC, operating as Gulfaar Group's dedicated Oman division, delivers world-class high-voltage electrical engineering, power plant maintenance, refinery turnaround support, and certified EPC technical staffing across Saudi Arabia, Oman, and the GCC.

400 kVSubstation CapabilityGIS/AIS & Relay Testing
24/7Plant TurnaroundsEmergency Shutdown Care
1,500+Technical WorkforceEngineers & Craft Staff
ISO / UtilityCertified & ApprovedENGIE, PDO & OQ Exposure
Strategic Partnership Architecture

An Integrated Ecosystem of Engineering Excellence

Combining regional EPC execution, high-voltage power engineering, industrial asset care, and renewable infrastructure.

Swipe alliances1 / 4
Saudi Arabia & GCC

Gulfaar Group

GCC Prime Contractor & Delivery

Turnkey project management, civil infrastructure, mobilization, and Saudi Vision 2030 localization across the Arabian Peninsula.

Muscat, Oman

Fortune Energy & Integrated Services

Regional Energy & Industrial Hub

Muscat-headquartered specialized power and industrial solutions provider supporting Oil & Gas, utility IPPs, and heavy industries.

Power Specialists

BSL Engineering Service

HV Substation, Testing & Protection

Specialized testing & commissioning up to 400kV, transformer oil filtration, protection relay automation, and GIS/AIS switchgear expertise.

Renewable Alliance

Qingdao Yueyang Engineering

Solar PV & Energy Storage (BESS)

Comprehensive balance-of-plant engineering, energy storage lifecycle solutions, and utility-scale renewable infrastructure consulting.

Core Technical Capabilities

Specialist Power & Industrial Services

Comprehensive capabilities analyzed directly from Fortune Energy & Integrated Services LLC's corporate dossier.

BSL Engineering JV Alliance

High-Voltage Substation Testing & Commissioning up to 400kV

Delivering primary and secondary electrical testing, numerical relay coordination, power transformer diagnostics, and switchgear commissioning across conventional utility grids and industrial mega-plants.

GIS / AIS Switchgear Testing (Up to 400kV)
Power Transformer Tan Delta & FRA Diagnostics
High-Vacuum Oil Dehydration & Filtration
Automated Omicron Numerical Relay Testing
VLF Cable Hi-Pot Withstand Testing
Earthing Grid & Step/Touch Potential Studies
Substation Commissioning
Transformer Testing
Switchgear Operation
Control Panel Wiring
Asset Diagnostic Matrix

Specialist Testing Fleet & Instrument Specifications

Calibrated testing and diagnostics complying strictly with IEC 61850, IEEE C57, and GCC utility standards.

Primary & Secondary Test Fleet
Swipe card or tap equipment
1 / 6
Numerical Relay Test Set

Omicron CMC 356

Flagship Relay Fleet
Rating / Output6x 32A / 4x 300V
Accuracy ClassClass 0.05% High Precision
Primary Application

Secondary injection testing for distance, differential, overcurrent, generator & motor protection relays.

IEC 61850 GOOSE / Sampled ValuesUtility Approved
Primary Injection & Diagnostic Tool

Omicron CPC 100

Primary Diagnostic
Rating / OutputUp to 800A / 2,000V AC
Accuracy ClassHigh Voltage / High Current Primary
Primary Application

CT/VT ratio, polarity, burden, excitation curve, transformer winding resistance, and contact resistance.

IEEE C57 / IEC 60076Utility Approved
Insulation Dissipation Factor

Tan Delta / Power Factor Set

Insulation Health
Rating / OutputUp to 12 kV Test Voltage
Accuracy ClassResolution 1x10⁻⁵ / 0.001%
Primary Application

Dielectric loss angle (Tan δ) measurement for high-voltage bushings, transformer windings, and rotating machinery.

IEEE C57.12.90 & IEC 60076-1Utility Approved
Transformer Oil Treatment

High-Vacuum Oil Purifier

Transformer Treatment
Rating / Output6,000 L/h Flow Capacity
Accuracy ClassMoisture < 5 ppm, BDV > 70 kV
Primary Application

On-site high-vacuum dehydration, degassing, and particulate filtration restoring dielectric breakdown voltage (BDV).

IEC 60422 / ASTM D1816Utility Approved
Very Low Frequency Test Set

VLF Hi-Pot Cable Test System

Cable Diagnostics
Rating / Output0.1 Hz / Up to 66 kV RMS
Accuracy ClassTrue Sinusoidal 0.1 Hz Output
Primary Application

AC withstand proof testing and Tan Delta diagnostic assessment for XLPE/EPR underground cables.

IEEE 400.2 / CENELEC HD 620Utility Approved
Critical Power Load Testing

DC Battery Load Bank

UPS & DC Care
Rating / OutputUp to 600A Discharge Current
Accuracy ClassIndividual Cell Logging
Primary Application

Automated constant-current capacity discharge and internal resistance measurement for utility UPS battery banks.

IEEE 450 / IEEE 1188 StandardsUtility Approved
Execution Comparison

Why Power Utilities Choose Fortune Integrated Delivery

Eliminating interface risk, reducing plant shutdown durations, and providing end-to-end commissioning under a single contract.

Swipe comparison criteria
1 / 6
Evaluation Criterion 1 of 6

Service Delivery Model

Fortune Energy & Integrated ServicesIntegrated

Single-Point Turnkey Accountability across Civil, MEP, Electrical & Testing

Traditional Disjointed Contractors:Fragmented multi-subcontractor handoffs with coordination delays
One Accountable PlatformGCC Localized
Evaluation Criterion 2 of 6

High-Voltage Testing & Commissioning

Fortune Energy & Integrated ServicesIntegrated

In-house primary/secondary testing up to 400kV with automated Omicron fleet

Traditional Disjointed Contractors:Relies on external third-party rental kits with unverified calibration
One Accountable PlatformGCC Localized
Evaluation Criterion 3 of 6

Transformer Diagnostics & Oil Filtration

Fortune Energy & Integrated ServicesIntegrated

Turnkey Tan Delta, FRA, turns ratio & on-site high-vacuum dehydration (BDV > 70kV)

Traditional Disjointed Contractors:Limited to basic insulation resistance; oil processing outsourced
One Accountable PlatformGCC Localized
Evaluation Criterion 4 of 6

Critical UPS & DC Power Support

Fortune Energy & Integrated ServicesIntegrated

OEM-agnostic certified servicing (Vertiv, Eaton, Socomec, ABB, Siemens) & load banking

Traditional Disjointed Contractors:Requires separate specialized vendor per OEM equipment
One Accountable PlatformGCC Localized
Evaluation Criterion 5 of 6

Plant Shutdown & Emergency Support

Fortune Energy & Integrated ServicesIntegrated

24/7 Emergency response teams with rapid mobilization across Oman & GCC

Traditional Disjointed Contractors:Standard business hours with lengthy mobilization lead times
One Accountable PlatformGCC Localized
Evaluation Criterion 6 of 6

Workforce Certification & Rigor

Fortune Energy & Integrated ServicesIntegrated

Multi-discipline certified team (CSWIP, NACE, API, NEBOSH, IEC 61850)

Traditional Disjointed Contractors:General manpower lacking utility and refinery operator pre-qualification
One Accountable PlatformGCC Localized
Track Record of Excellence

Relevant GCC Project Exposure

Delivering critical electrical services, power plant maintenance, and shutdown support for leading regional operators.

ENGIE STOMOGCC Exposure

Barka II Power & Desalination Plant

Independent Water & Power Project (IWPP)

CCR UPS & Rectifier Servicing, critical DC power systems, battery bank capacity discharge testing & maintenance.

Successfully Delivered
Utility OperatorGCC Exposure

Ibri II Solar Independent Power Plant

500 MW Utility-Scale PV IPP

Substation interface testing, medium-voltage switchgear commissioning, and electrical balance of plant.

Successfully Delivered
Sohar Power CompanyGCC Exposure

Sohar III Independent Power Plant

1,710 MW Combined Cycle Power Plant

Power plant electrical support, protection relay testing, MCC maintenance, and transformer lifecycle services.

Successfully Delivered
Petroleum Development OmanGCC Exposure

PDO Electrical Infrastructure Projects

Upstream & Midstream Oil & Gas Facilities

Substation commissioning, transformer oil treatment, high-voltage cable termination, and E&I installation.

Successfully Delivered
OQ GroupGCC Exposure

OQ Refinery & Petrochemicals

Downstream Refinery & Process Plants

Plant shutdown support, rotating/static equipment maintenance, valve servicing, and electrical turnaround works.

Successfully Delivered
International EPC ContractorGCC Exposure

Majnoon Oil Field ME&I Project

Major Oil Field Development

Mechanical, Electrical & Instrumentation general services, cable laying, panel erection, and field commissioning.

Successfully Delivered
Global Compliance & Standards

Certified to the World's Highest Rigor

Full compliance with international standards, ISO management certifications, and GCC national operator specifications.

ISO 9001:2015Quality Management Systems
ISO 14001:2015Environmental Management
ISO 45001:2018Occupational Health & Safety
IEC 61850Substation Automation & Protection
IEEE C57 / C37Power Transformer & Breakers
Oman DGRP / NamaUtility Pre-Qualification Approved
Direct Engineering Collaboration

Request a Proposal or Technical Dossier

Connect directly with Fortune Energy & Gulfaar's technical team to discuss substation testing, transformer maintenance, plant shutdowns, or specialized manpower.